X Proof Pheumatic Applications

JP2A-P Desiccant Air Dryer System

_P2B-P
Zero loss condensate auto drain
Select an image to enlarge
Bluetooth technology
Records number of dryer cycles Will not drain air from system overnight
Tracks service history Service updates sent by text message
Selectable timed regeneration cycles 90-second cycle for high flow120-second cycle for moderate flow
Regenerates only when compressor is pumping Test cycles for service analysis
Installs on Air Pak dryers currently in service Cartridge-style replacement valves
0.3 micron filtration Spin on / off desiccant cartridges
Optional zero-loss condensate auto drain (PDF)
Regeneration orifice
.014
Max flow @ 100% duty
14 CFM
Max flow @ 70% duty
27 CFM

Twin Tower w/MLT

The descriptions detailed in this twin tower schematic represent the sequencing of airflow as it relates to the actual drying process and transition – wet to dry – within all dryer systems including both Programmable Logic (PLC) and Pneumatically Controlled (PC) systems

5HP-7.5HP 20CFM

SERVICE COMPONENTS w/ 8LB. Desiccant Cartridges

Service Schematic AIR-PAK Dryer w/ PLC

(Represents one dryer within PLC dryer system)

<...e Sequence 180 sec.

Cartridge 1 regenerates for 45 sec. Cartridge 2, 3, 4 receives wet air. PLC switches

Cartridge 2 regenerates for 45 sec. Cartridge 1, 3, 4 receives wet air. PLC switches

PC Total Cycle Sequence 240 sec.

Cartridge 1 regenerates for 60 sec. Cartridge 2, 3, 4 receives wet air. PC switches

Cartridge 2 regenerates for 60 sec. Cartridge 1, 3, 4 receives wet air. PC switches

_P2B-P

SERVICE COMPONENTS w/ 8LB. cartridges

20HP-80CFM-Standard-Cannister-PLC-Schematic

Pneumatic Purge Service Components

Drag or scroll horizontally to see full table

Illustration Part Number Air-Pak Explosion Proof Contents of Service Kit
2 4 6 8 12
Desiccant Cartridges 619832 1 2 3 4 6 Grey Cartridges – Full Service Kit
Includes 2 each desiccant cartridges, inlet & purge valves
619700 1 2 3 4 6 Blue Cartridges – Full Service Kit
Includes 2 each desiccant cartridges, inlet & purge valves
619750 1 2 3 4 6 White Cartridges – Full Service Kit
Includes 2 each desiccant cartridges, inlet & purge valves
619830 1 2 3 4 6 Grey Desiccant Cartridge
Includes 2 desiccant cartridges
619704 1 2 3 4 6 Blue Desiccant Cartridge
Includes 2 desiccant cartridges
619951 1 2 3 4 6 White Desiccant Cartridge
Includes 2 desiccant cartridges
Color Cartridges eight 650830 1 2 3 4 6 Grey Cartridges – Full Service Kit
Includes 2 each desiccant cartridges, inlet & purge valves
650700 1 2 3 4 6 Blue Cartridges – Full Service Kit
Includes 2 each desiccant cartridges, inlet & purge valves
650951 1 2 3 4 6 White Cartridges – Full Service Kit
Includes 2 each desiccant cartridges, inlet & purge valves
4055A002 1 2 3 4 6 Grey Desiccant Cartridge
Includes 2 desiccant cartridges
4055A020 1 2 3 4 6 Blue Desiccant Cartridge
Includes 2 desiccant cartridges
4055A012 1 2 3 4 6 White Desiccant Cartridge
Includes 2 desiccant cartridges
Inlet and Purge Valve 619702 1 2 3 4 6 Valve Service Kit
Includes 2 inlet check valves, 2 purge valves
Regen Valve Kit 619708 1 ~ ~ ~ ~ .014 Regeneration valve kit
619715 1 2 ~ ~ ~ .030 Regeneration valve kit
619730 1 ~ 3 4 6 .060 Regeneration valve kit
2-Stack-Pneumatic-Logic-Controll 619985 1 1 1 1 1 Two (2) Stack Pneumatic Controller
Includes mounting hardware
619987 ~ 1 ~ 1 ~ Four (4) Stack Pneumatic Controller
Includes mounting hardware
6-Stack-Pneumatic-Logic-Controll 619989 ~ ~ 1 ~ 1 Six (6) Stack Pneumatic Controller
Includes mounting hardware
Pneumatic-timer-Valve 619986 2 4 6 8 12 Pneumatic timer valve with air chamber
5-2-Valve-for-pneumatic-timer 619988 2 4 6 4 6 5/2 Valve for pneumatic timer
Acrylic-Manifold-for-pneumatic-controller 619981 1         2 stack pneumatic logic manifold
619983   1   1   4 stack pneumatic logic manifold
619984     1   1 6 stack pneumatic logic manifold
Pressure Relief Valve 619740 1 2 3 4 6 Pressure Relief Valve
Disc Filter 619860 1 2 3 4 6 Disc Filter
Air dryer adapter plate with stud 619734 1 2 3 4 6 RH Adapter Plate w/ stud – Blue, White, Purple Cartridges
619735 1 2 3 4 6 LH Adapter Plate w/ stud – Blue, White, Purple Cartridges
619936 1 2 3 4 6 LH Adapter Plate w/ stud – Grey Cartridges
619937 1 2 3 4 6 RH Adapter Plate w/ stud – Grey Cartridges
Cartridge stud 619760 4 6 10 12 18 Cartridge Stud for Grey Cartridges
619765 4 6 10 12 18 Cartridge Studs for Blue, White, Purple Cartridges
Mufflers 619770 4 6 10 12 18 Small Mufflers (optional)
619915 4 6 10 12 18 Large Mufflers (optional)
  619942 1 ~ ~ ~ ~ 2 Stack Wall Strut w/slot for two cartridge dryer system
619945 1   2 3 8  4 Stack Wall Strut w/slot for two cartridge dryer system
619950   1   2 4  6 Stack Wall Strut w/slot for two cartridge dryer system
Wall Bracket 619990 2 3 5 6 9 Wall Mount Bracket

Wiring guides

Air-Pak Select Purge wiring options.

Three ways to connect your dryer. Tap any diagram to enlarge it, or download the PDF for each option.

OPTION 01

Direct to air compressor pressure control

Connecting the 4-wire system to the air compressor’s pressure control.

Direct to compressor
BlackConnect to 120 VAC power source
WhiteConnect to 120 VAC common neutral
GreenConnect to earth ground
RedAccepts 24 VDC to 480 VAC. Connect the signal from either:

  • the compressor pressure switch on/off side, or
  • the compressor inlet valve solenoid signal

Operation check

ONVoltage applied to Red wire (compressor motor running)Dryer cycles and regenerates
OFFNo voltage applied (compressor motor off)Dryer cycles and regeneration flow stop
Note: If the Red wire is never connected, Air-Pak Select Purge still operates automatically, but regeneration air continues while the compressor motor is off. The Red wire can be connected at any time (e.g., when the dryer is moved to another compressor), and the microprocessor resets automatically to work as described above.

OPTION 02

Wired to a dedicated switch

For a dryer installed at point of use, e.g., a paint booth. Air-Pak Select Purge can connect directly to a 110 V dedicated switch.

Select-Air-to-Dedicated-Switch
BlackConnect to 120 VAC dedicated ON/OFF switch
Wht/RedConnect to 120 VAC common neutral
GreenConnect to earth ground
Air-Pak Select Purge is powered when the remote switch is turned “ON” or “OFF.”

OPTION 03

Plugged into a wall receptacle

For a dryer installed at point of use, e.g., a paint booth. Air-Pak Select Purge can connect directly to a 110 V dedicated switch.

Select Air Plugged Directly to Wall Receptacle
BlackConnect to 120 VAC dedicated ON/OFF switch
Wht/RedConnect to 120 VAC common neutral
GreenConnect to earth ground
Air-Pak Select Purge is powered when the remote switch is turned “ON” or “OFF.”

Custom sizing

Many other sizes available upon request.

Request a Size

Air Pak Air Dryer Owner's Manual PM Schedule